RTASCEC - Wired room temperature thermostat with ECO and C/O inputs

Main features

  • Child safety.
  • Room temperature control.
  • Connection to a thermal actuator or to a wired terminal block for a underfloor heating/cooling system.
  • Wired transmission of the set temperature and the measured temperature.
  • Frost protection.
  • Heating to Cooling and vice-versa switchovers.
  • Temperature decrease (Eco mode): lowering of the temperature set in Comfort mode (by 3.5°C).
  • Setting of desired temperature, with Comfort temperature range (20°C to 23°C) displayed; contact status indicator light ON = switched on.

Main features

  • Child safety.
  • Room temperature control.
  • Connection to a thermal actuator or to a wired terminal block for a underfloor heating/cooling system.
  • Wired transmission of the set temperature and the measured temperature.
  • Frost protection.
  • Heating to Cooling and vice-versa switchovers.
  • Temperature decrease (Eco mode): lowering of the temperature set in Comfort mode (by 3.5°C).
  • Setting of desired temperature, with Comfort temperature range (20°C to 23°C) displayed; contact status indicator light ON = switched on.

Product plus points

  • Assistance for the partially-sighted - raised reference points.
  • Sober design - suitable for traditional or contemporary interiors.
  • Child safety: rotary knob locking restricts changes of temperature settings, in respect of a minimum temperature, a maximum temperature or of a temperature range.
  • Practical: the product has a small footprint.
  • Excellent ergonomics and user experience when carrying out settings using the rotary knob.
  • Electronic analogue-control room temperature thermostat for wired control of 230V and 24V underfloor heating.
  • Frost protection: the Frost protection feature allows the systems in a home to be protected against freezing, by maintaining a temperature of about 8°C.
  • Wired CO input for changeover from Heating to Cooling and vice-versa.
  • Wired NR input for temperature decrease which is set at 3K.
  • On/Off temperature control.
  • 2 fitting options:
    • on a junction box.
    • salient.

Technical characteristics

  • Power supply
    • Voltage when in use: 24VAC or 230V +/-10% 50Hz.
    • Typical power consumption: 2.3mA.
    • Electronic output: 24VAC +/- 10%, 50Hz, 0.7A maximum or 230VAC +/- 10%, 50Hz, 1A maximum.
    • Connection: by means of clamp terminals for cables with 0.5 square mm to 1.5 square mm cross-sections.
  • Safety
    • Standards: EN60730-1/EN60730-2-9.
    • Software: Class A.
    • Environmental pollution degree: 2.
    • Overvoltage category III, 4kV surge.
  • Environment
    • Protection rating: IP20.
    • Class: Class III.
    • Operating temperature: 0°C to +40°C.
    • Temperature setting range: +7°C to +30°C.
    • Storage temperature: -10°C to +50°C.

CODESREFERENCES
RTASCECIMHA Wired analogue 230V thermostat, NR and CO, white, for 230V underfloor heating system
RTASCVECIMHA Wired analogue 24V thermostat, NR and CO, white, for 24V underfloor heating system

RANGE OF THERMOSTATS FOR UNDERFLOOR HEATING


Download imh-fp_rtascec_eng_v04_121017.pdf