Main features

  • Connection to a wired 24V or 230V underfloor heating/cooling terminal block,
    with or without dew point detection.
  • Wired transmission of commands to terminal blocks:
    • 3-position remote control: Auto, Comfort, Eco.
    • 4-position remote control: Auto, Comfort, Eco and Cooling.
  • Modification and viewing of operating modes, contact status light ON means switched on.

Wired analogical remote controls

RCARE3

Remote control with 3 operating modes: Auto, Comfort and Eco
+

Main features

  • Connection to a wired 24V or 230V underfloor heating/cooling terminal block,
    with or without dew point detection.
  • Wired transmission of commands to terminal blocks:
    • 3-position remote control: Auto, Comfort, Eco.
    • 4-position remote control: Auto, Comfort, Eco and Cooling.
  • Modification and viewing of operating modes, contact status light ON means switched on.

Product plus points

  • Assistance for the partially-sighted - raised reference points.
  • Sober design - suitable for traditional or contemporary interiors.
  • Excellent ergonomics and user experience when carrying out settings using the rotary knob.
  • Compatible with wired analogue- and digital-control room temperature thermostats.
  • The remote control enables you to change the operating mode of a single area in the system - or of the complete system - from a central point.
  • Option of using two or more remote controls in the same house and of dividing the system into different areas.
  • Wired CO output for switching from heating to cooling temperature regulation, and vice-versa.
  • Wired NR output for lowering the temperature.
  • 2 wall installation options :
    • on a junction box.
    • salient.

Technical characteristics

  • Power supply
    • Power supply: two AAA/ LR03 1.5V alkaline batteries (lifetime about 2 years).
    • Typical power consumption: 0mA.
    • Max. output current: 50mA for 24V and 230V.
    • Connection: by means of clamp terminals for cables with 0.5 square mm to 1.5 square mm cross-sections.
  • Safety
    • Standards: EN60730-1/EN60730-2-9/EN60730 Class II (230V), Class III (24V).
    • Environmental pollution degree: 2.
    • Overvoltage catergory II, 2.5 kV surge.
  • Environment
    • Protection rating: IP20.
    • Operating temperature (T60): 0°C to 60°C.
    • Storage temperature: from -10°C to +60°C.

CODESREFERENCES
RCARE4IMHA Analogue wired 4-position remote control, white, for underfloor heating
RCARE3IMHA Analogue wired 3-position remote control, white, for underfloor heating

REMOTE-CONTROLLED UNDERFLOOR HEATING RANGE


Download imh-fp_rcare_eng_v02_121017.pdf